MODEL
MAX KW 220 V
VOLTS
    MAX AMP.240 V
RECOMMENDED BREAKER
                        APPLICATION
Titan
Tankless 
SCR-4
N-210
21.0 KW
240 V
88
50 AMP x 2 each with #6 AWG Wire
 
4 Bath Homes
or Colder
Climate
N-180
18.0 KW
240 V
77



40 AMP x 2 each with #6 AWG Wire
                  3 Bath Homes     
                    or Colder     
                      Climate
Titan Tankless
SCR-3
N-160
12.0 KW
208 V
55




60 AMP  Double Pole
Breaker #6 AWG Wire



  21/2 Bath Homes:
Larger Homes, and Colder Climates     
   
 

  New  apartments  and homes   with 208 Vac
N-160
16.0 KW
240 V
66




70 AMP Double Pole
Breaker #6 AWG Wire
Titan
Tankless
SCR-2
N-120
11.8 KW
240 V
54




60 AMP Double Pole
Breaker #6 AWG Wire

2 Bath Homes or 2 Baths larger apartments, Warmer Climates
 N-100
10.8 KW
240 V
49



50 AMP Double Pole Breaker #8 AWG Wire 

1 Bath Homes or 2 baths condo-apartment
Warmer Climates
N -85



8.5 KW
240 V
38




40 AMP Double   Pole  Breaker        #8 AWG Wire      
2 Baths apartment or 1 bath apt w/ low flow shower heads, Warmer Climates
See Temperature Rise table Below

Note: Temp. Rise, is the temperature the tankless water heater will add to the temperature of the cold water,depending on how much water is being used at any time.



Temp. Rise Chart Titan Tankless N-85
Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 69 46 34 28 23 17 15

Tankless 
Installation Dg. N-85.pdf
              

                                                             Temp. Rise Chart Titan Tankless N-100
 Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 87 58 44 35 29 25 18
Tankless 
Installation Dg. N-100.pdf
          


                                                                                 Temp. Rise Chart Titan Tankless N-120
 Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 87 64 48 38 32 28 24
Tankless 
Installation Dg. N-120.pdf 


                                                                                 Temp. Rise Chart Titan Tankless N-160
 Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 109 73 55 44 36 31 27
Tankless 
Installation Dg.N-160.pdf

      

                                                                                 Temp. Rise Chart Titan Tankless N-180
Flow Rate (Gallons Per Minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm 4.5 gpm 5.0 gpm
Temp. Rise(Fahrenheit degrees) 122 81 61 49 41 35 31 27 25

Tankless 
Installation Dg.N-180.pdf
 

     Temp. Rise Chart Titan Tankless N-210

Flow Rate (Gallons Per Minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm 4.5 gpm 5.0 gpm
Temp. Rise(Fahrenheit degrees) 143 95 71 57 48 41 38 32 29

Tankless 
Installation Dg. N-210.pdf
   


      Typical Flow Rates in Gallons per Minute (gpm)
Fixture Type Lavatory Bathtub Shower Kitchen Sink Pastry Sink Laundry Sink Dish Washer
Flow Rates 0.5 2.0-4.0 1.5-3.0 1.0-1.5 1.5-2.5 2.5-3.0 1.0-3.0