MODEL
MAX KW 220 V
VOLTS
    MAX AMP.240 V
RECOMMENDED BREAKER
                        APPLICATION
Titan
 
SCR-4
N-210
21.0 KW
240 V
88
50 AMP x 2 each with #6 AWG Wire
 
4 Bath Homes
or Northern
Climate
N-180
18.0 KW
240 V
77



40 AMP x 2 each with #6 AWG Wire
                       3 Bath Homes  
                        or Northern 
                           Climate
Titan
 
SCR-3
N-160
12.0 KW
208 V
55




60 AMP  Double Pole
Breaker #6 AWG Wire



 .21/2 Bath Homes:
Larger Homes, and Nothern Climates     
   
 

.New  appartments   and homes with 208 Vac
N-160
16.0 KW
240 V
66




70 AMP Double Pole
Breaker #6 AWG Wire
Titan

SCR-2
N-120
11.8 KW
240 V
54




60 AMP Double Pole
Breaker #6 AWG Wire

2 Bath Homes or 2 Baths larger apartments
 
 N-100
10.8 KW
240 V
49



50 AMP Double Pole Breaker #8 AWG Wire 

1 Bath Homes or 2 baths condo-apartment
N -85



8.5 KW
240 V
38




40 AMP Double   Pole  Breaker        #8 AWG Wire      
2 Baths apartment or 1 bath apt w/ larger shower heads
See Temperature Rise table Below

Note: Temp. Rise, is the temperature the tankless water heater will add to the temperature of the cold water,depending on how much water is being used at any time.



Temp. Rise Chart Titan N-85
Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 69 46 34 28 23 17 15


N-85 Installation.pdf     

                                                                      Temp. Rise Chart Titan N-100
 Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 87 58 44 35 29 25 18

N-100 Installation.pdf   


                                                                                                Temp. Rise Chart Titan N-120
 Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 87 64 48 38 32 28 24

N-120 Installation.pdf
  


                                                                                                 Temp. Rise Chart Titan N-160
 Flow Rate (Gallons per minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm
Temp. Rise(Fahrenheit degrees) 109 73 55 44 36 31 27


N-160 Installation.pdf  


                                                                                               Temp. Rise Chart Titan N-180
Flow Rate (Gallons Per Minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm 4.5 gpm 5.0 gpm
Temp. Rise(Fahrenheit degrees) 122 81 61 49 41 35 31 27 25


 N-180 Installation.pdf



  Temp. Rise Chart Titan N-210
Flow Rate (Gallons Per Minute) 1.0 gpm 1.5 gpm 2.0 gpm 2.5 gpm 3.0 gpm 3.5 gpm 4.0 gpm 4.5 gpm 5.0 gpm
Temp. Rise(Fahrenheit degrees) 143 95 71 57 48 41 38 32 29


N-210 Installation.pdf  
 


Typical Flow Rates in Gallons per Minute (gpm)
Fixture Type Lavatory Bathtub Shower Kitchen Sink Pastry Sink Laundry Sink Dish Washer
Flow Rates 0.5 2.0-4.0 1.5-3.0 1.0-1.5 1.5-2.5 2.5-3.0 1.0-3.0



Tankless USA Inc.  4815  NW 79th Ave ,  Unit 5  Miami, Fl 33166 
For Installation Services Call now!, 786 316 6693 to place the order


Sales: 786 316 6693 
Transaction Processing